产品简介: | |||
Steel processors use water to cool bearings on the | |||
rollers of their continuous casting machines. If the | |||
casting machine loses water flow, the bearings will fail. | |||
Alarms are required to notify casting machine operators | |||
of this crucial loss of flow condition. The T21 flow | |||
switch is installed in each cooling water line to ensure | |||
this critical low-flow alarm. | |||
The T21 can be used to monitor lube oil on bearings | |||
and gears in rolling mills; and since a single gear costs | |||
several hundred thousand dollars, its protection is vital | |||
to the operation of the plant. | |||
The T21 can also monitor the flow of cooling water on | |||
pump seals in steel plants and furnaces. | |||
详细说明: | |||
l Wide operating process | |||
temperature range of | |||
-100 to 392oF | |||
l Removable, plug-in electronics | |||
board | |||
l Free of all moving parts that | |||
can stick, coat or fail | |||
l Self-heating sensor design | |||
l Application flexibility | |||
l Simplifies wiring | |||
l High reliability | |||
l Improves response time and | |||
sensor durability | |||
Input Power 115 VAC or 230 VAC, 50/60 Hz | |||
24 VDC (nominal) | |||
Output Type 5A DPDT @ 250 VAC | |||
Humidity 99% Non-condensing | |||
Accuracy +0.5% of set point - 50oF range | |||
Set Point Range Gases 0.5 to 500 feet/second | |||
(Flow) Liquids 0.01 to 5 feet/second | |||
Repeatability +1.0% of set point | |||
Response Time 0.5 to 10 seconds | |||
Sensor Length 2 inches to 120 inches* | |||
Enclosure Environmental Rating NEMA 4 | |||
Conduit Connection 3/4” NPT(F) | |||
Stability T emperature compensated | |||
over entire range | |||
Ambient T emperature Range -40 to 140oF | |||
(-40 to 60oC) | |||
Process T emperature Range -100 to 392oF | |||
(-70 to 200oC) | |||
Process Pressure Range Vacuum to 3000 psig |
SOR T21 液位开关